VARIVENT® 24/7 PMO

VARIVENT® 24/7 PMO

Order

 

VARIVENT® 24/7 PMO

Mixproof Separation
The VARIVENT® 24 / 7 PMO Valve® 2.0 is almost exclusively used in dairy applications subject to the regulations of the Pasteurized Milk Ordinance (PMO). Primarily, this concerns dairies in the United States. These valves are used for mixproof shut-off of incompatible products at pipe junctions.
When the valve is closed (non-actuated position), there are always two seals between the separated pipelines. If one seal is defective, the resulting leakage will be directed through the leakage outlet into the periphery, without mixing with the product in the second pipeline.

Dairy plants that are subject to the PMO use this valve in all non-aseptic process areas, e.g. milk reception, raw milk storage and distribution systems, pasteurizer in- and outlets and filling lines. This method prevents any mixture between a product pipe and a pipe carrying cleaning media.

Double-seat valves
OD 1 ½” – OD 6″

Lifting actuator

The valves are always equipped with a lifting actuator which permits individual lifting of an individual valve disc during the particular pipe cleaning. The 24/7 PMO Valve® 2.0 satisfies the strict requirements of the PMO (Pasteurized Milk Ordinance) and is certified acc. to 3-A Standard 85-02 for performing the lift function while milk or milk products are being transported in the other pipeline.

In this case, the cleaning media passes the seal of the lifted valve disc, cleans the leakage chamber and then flows out through the leakage outlet into the periphery. Therefore, it is possible to clean all surfaces that come into contact with the product, including the seal surfaces of the valve disc seals.

Article “Item 12p. Cleaning and sanitizing of containers and equipment” of the PMO stipulates that each surface that comes into contact with the product must be cleaned at least once a day. For this reason, the 24 / 7 PMO Valve® 2.0 is equipped with a balancer cleaning device as standard. During lifting of the lower valve disc, a gap is automatically left open between the lower balancer seal and the valve disc. Cleaning media can thus get into the balancer cleaning device and clean the surface of the balancer. In this way, the valve meets the requirements of Item 12p. of the PMO without requiring further measures to be taken. Optionally, however, the valves can also be delivered without a balancer cleaning device if the surface will be cleaned in another way, e.g. by a full stroke during cleaning.